<Error>
<ErrorNumber>15182</ErrorNumber>
<ErrorFamily>Autoloader</ErrorFamily>
<ErrorMessage>
ALE: plate on picker, remove plate from unload ramp
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Platesetter_3244</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><NumberedList>
<ListItem><Text>Proximity sensor failure.</Text></ListItem>
<ListItem><Text>Vacuum sensor failure.</Text></ListItem>
</NumberedList></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Remove plate from picker or select resume or clear.
</text></DescriptionText>
</OperatorAction>
<Cause>
This error is generated if there was a plate detected on the picker
in one of the following scenarios:
- Detected by VACUUM
</Cause>
<Cause>
Before beginning the "process" sequence the process status is checked:
If a plate is detected on picker by picker vacuum above threshold or if the picker plate_loc
status flag does not show "picker empty".  then this error is reported and the plate cannot
be ejected to processor as another plate is hanging on the picker.
- Detected by the PROXIMITY DETECTOR,
</Cause>
<Cause>
During a ale_pick_status_ok check which is performed before a pick is started (pick0)
</Cause>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../nvs/sat_cal_pvt.xml</LinkAddress><LinkTitle>NVS: sat pvt</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:32:55 2008 PST
</Updated>
<Links>
</Links>
</Error>